Technical Specifications
- Input voltage range: Up to 18V per battery, 36V total.
- Turn on level: 27,3V +/- 1%.
- Turn off level: 26,6V +/- 1%.
- Current draw when off: 0,7 mA.
- Midpoint deviation to start balancing: 50 mV.
- Maximum balancing current: 0,7A (when deviation > 100 mV).
- Alarm trigger level: 200 mV.
- Alarm reset level: 140 mV.
- Alarm relay: 60V / 1A normally open.
- Alarm relay reset: Two terminals to connect a push button.
- Over temperature protection: Yes.
- Operating temperature: -30 t0 +50°C.
- Humidity (non-condensing): 95%.
- 5 year warranty.
Enclosure
- Colour: Blue (RAL 5012).
- Connection terminals: Screw terminals 6 mm² / AWG10.
- Protection category: IP22.
- Weight: 0,4 kg.
- Dimensions (h x w x d): 100 mm x 113 mm x 47 mm.
Important:
All solar products, power systems, water heating and gas products and their components must be installed by appropriately qualified personnel. All installations must adhere to local wiring regulations and standards. Sustainable Online will not be held liable for any product malfunctions as a result of incorrectly installed systems.