Geyserwise Max Geyser Controller with Wifi

Geyserwise Max Geyser Controller with Wifi

Geyserwise Max Geyser Controller with Wifi

Regular price R 3,584.00 incl. VAT Sale price R 2,866.95 incl. VATSave R 717.05
R 2,49300 excl. VAT
incl. VAT/


Tax included. Shipping calculated at checkout.
  • Secure online payments

Product Description:

The Geyserwise Max Geyser Controller with Tuya Module is a Smart Wifi Geyser Controller used in pumped solar water heating systems.

Use as a geyser timer or use as timer on a thermosyphon solar system.

  • Clear display of water temperature, time, day, heating mode and malfunction conditions.
  • Auto or manual heating.
  • Easy temperature setting to your requirements (30 – 75°C) factory default is 55°C.
  • Four different temperature settings.
  • Daily programmable timer with four time settings.
  • Error conditions alert by warning code E1 to E7.
  • Electronic thermostat with mechanical thermal cut-out at 90°C. Please note the cut-out temperature for solar systems expected to reach temperatures above this temperature.

Use as timer and differential control on 12V or 220V pumped solar system.

  • Clear display of water temperature, time, day, heating mode and malfunction conditions on solar system and geyser.
  • Auto or manual heating.
  • Easy temperature setting to your requirements (30 – 75°C) factory default is 55°C.
  • Four different temperature settings.
  • Daily programmable timer with four time settings.
  • Error conditions alert by warning code E1 to E9.
  • Electronic thermostat with mechanical thermal cut-out at 90°C. Please note the cut-out temperature for systems expected to reach temperatures above this temperature.
  • Differential controller 12V and 220V systems.

Download the Tuya Smart App and manage your geyser from your phone anywhere in the world.

Download For IOS 

Download for Android

  • View your geyser temperatures
  • Set your temperatures
  • Switch Your Geyser On And Off from virtually anywhere.
  • Manage Your Geyser like a wifi geyser controller.

Technical Parameters

  • Operating voltage 230VAC / 50HZ.
  • Main Relay contact rating 30AMP (Max 4KW).
  • Secondary relays pump and solenoid 5Amp.
  • Operating voltage range 220V – 250V AC.
  • Earth leakage protection at 25MA action time = 0,1 second.
  • Temperature display range 0 – 99°C (“-5” when below -5°C “EA” when above 99°C).
  • High temperature warning above 84°C.
  • Temperature setting ranges 30 – 75°C (heating water electrically).
  • Heat failure – when increase at a rate of less than 4°C per hour.
  • Electronic thermostat with mechanical thermal cut-out at 90°C.
  • Dry heat detection – empty cylinder.
  • Temperature tolerance ± 2%.
  • Temperature differential setting 1°C.
  • Switching differential 6°C.
  • 2nd temperature probe for solar.
  • Solar differential 7°C – 15°C. Default is 7°C.
  • Temperature probe failure detection for both collector and tank.
  • Temperature probe range for geyser is -30 to + 130°C.
  • Temperature probe range for collector is -30 to + 260°C.
  • Isolate both L + N when in off state.
  • Collector antifreeze protection at 0°C – 10°C. Default is 5°C.

Important:

All solar products, power systems, water heating and gas products and their components must be installed by appropriately qualified personnel. All installations must adhere to local wiring regulations and standards. Sustainable Online will not be held liable for any product malfunctions as a result of incorrectly installed systems.

Recently viewed