Technical Specifications
SmartSolar Charge Controller: 150/60
- Battery voltage: 12/24/48V Auto Select (software tool needed to select 36V).
- Rated charge current: 60A.
- Nominal PV power, 12V: 860W.
- Nominal PV power, 24V: 1720W.
- Nominal PV power, 36V: 2580W.
- Nominal PV power, 48V: 3440W.
- Max. PV short circuit current: 50A (max 30 A per MC4 conn.)
- Maximum PV open circuit voltage: 150V absolute maximum coldest conditions (145V start-up and operating maximum).
- Maximum efficiency: 98%.
- Self-consumption: < 35mA @ 12V / 20mA @ 48V.
- Charge voltage 'absorption' Default setting: 14,4 / 28,8 / 43,2 / 57,6V (adjustable with: rotary switch, display, VE.Direct or Bluetooth).
- Charge voltage 'float' Default setting: 13,8 / 27,6 / 41,4 / 55,2V (adjustable: rotary switch, display, VE.Direct or Bluetooth).
- Charge voltage 'equalization' Default setting: 16,2V / 32,4V / 48,6V / 64,8V (adjustable)
- Charge algorithm: multi-stage adaptive (eight pre-programmed algorithms) or user defined algorithm.
- Temperature compensation: -16 mV / -32 mV / -64 mV / °C.
- Protection: Battery reverse polarity (fuse, not user accessible) / PV reverse polarity / Output short circuit / Over temperature.
- Operating temperature: -30 to +60°C (full rated output up to 40°C).
- Humidity: 95%, non-condensing.
- Maximum altitude: 5000m (full rated output up to 2000m).
- Environmental condition: Indoor, unconditioned.
- Pollution degree: PD3.
- Data communication port: VE. Direct or Bluetooth.
- Remote on/off: Yes (2 pole connector).
- Programmable relay: DPST AC rating (240VAC) / 4A DC rating (4A up to 35VDC, 1A up to 60VDC).
- Parallel operation: Yes: up to 10 units can be synchronized with Bluetooth
Enclosure
- Colour: Blue (RAL 5012).
- PV terminals: 35 mm² / AWG2 (Tr models).
- Battery terminals: 35mm² / AWG2.
- Protection category: IP43 (electronic components), IP22 (connection area).
- Weight: 3 kg.
- Dimensions (h x w x d) in mm Tr models: 185mm x 250mm x 95mm.
Standards
Safety: EN/IEC 62109-1, UL 1741, CSA C22.2
Stored Trends
- Data Stored: Battery voltage, urrent and temperature, as well as ;pad putput current, PV voltage and PV Current.
- Number of days data is stored: 46
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5 V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1 V.
2) A PV array with a higher short circuit current may damage the controller.
3) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels
 Maximum current per MC4 connector: 30 A (the MC4 connectors are parallel connected to one MPPT tracker)
Important:
All solar products, power systems, water heating and gas products and their components must be installed by appropriately qualified personnel. All installations must adhere to local wiring regulations and standards. Sustainable Online will not be held liable for any product malfunctions as a result of incorrectly installed systems.